Furnace Shutting Down on Limit Switch in Buffalo Grove, IL

How High Static Pressure and Incorrect Installation Caused Heating Failure

Location: Buffalo Grove, Illinois

Service Type: Furnace Diagnostic & Repair

Home Size: Approx. 2,000 sq ft

Furnace Type: Two-Stage Gas Furnace (66,000 BTU)

furnace repair buffalo grove

Customer Complaint

A homeowner in Buffalo Grove, IL contacted Four Elements Service because their furnace was:

  • Turning on briefly and shutting off
  • Failing to maintain indoor temperature
  • Running frequently but not heating the home properly

The homeowner was also concerned that the furnace might be too small for the home.

Initial Inspection & Findings

Upon arrival, our technician performed a full furnace and airflow diagnostic. Several issues were discovered during the inspection.

1. Furnace Tripping the High-Limit Switch

The furnace was shutting down due to the high-temperature limit switch, a safety device designed to protect the heat exchanger from overheating.

This immediately indicated a serious airflow restriction.

2. Excessive Static Pressure

Total external static pressure was measured at approximately 1.0″ w.c., which is well above manufacturer specifications for this type of furnace.

High static pressure causes:

  • Reduced airflow
  • Overheating of the heat exchanger
  • Short cycling
  • Premature component failure

3. Restrictive High-MERV 1-Inch Filter

high-MERV 1-inch air filter was installed in the system.
While marketed as “high-efficiency,” this type of filter significantly restricts airflow in most residential systems.

In this case, the filter alone was enough to push the system into unsafe operating conditions, causing the furnace to overheat and shut down on limit.

4. Incorrect Thermostat Wiring

Additional inspection revealed improper thermostat wiring:

  • RC and RH were separated even though the system uses a single transformer
  • Heating stages were not configured correctly for the existing thermostat

This wiring configuration can cause inconsistent heating operation and improper staging.

5. Installation & System Design Concerns

The furnace installation and duct configuration were not ideal and contributed to airflow limitations.
While the furnace size itself (66,000 BTU) is generally appropriate for a 2,000 sq ft home in the Buffalo Grove / Chicago climate, poor airflow can make even a correctly sized furnace perform poorly.

Corrective Actions Performed

Our technician completed the following repairs and corrections:

✔ Thermostat Wiring Corrected

  • Reconnected RC to RH to match the single-transformer system
  • Installed a jumper between W1 and W2 so the two-stage furnace could operate properly with the existing thermostat

✔ Airflow Restriction Resolved

  • Removed the restrictive high-MERV 1″ filter
  • Recommended proper filtration options that allow safe airflow:

✔ System Tested

  • Furnace was run through a complete heating cycle
  • High-limit switch no longer tripped
  • Temperature rise returned to safe operating range
  • Furnace operated normally without short cycling

Final Results

After correcting airflow and wiring issues:

  • Furnace operated continuously and safely
  • Home temperature stabilized
  • Limit switch issues were eliminated
  • Customer concerns about furnace size were resolved

This case confirmed that the issue was not furnace capacity, but rather airflow restriction and installation errors.


Key Takeaway for Homeowners in Buffalo Grove

  • Restrictive air filters
  • Undersized or poorly designed ductwork
  • Incorrect thermostat wiring

Installing a high-MERV filter without considering airflow can actually damage your furnace and reduce comfort.Professional Recommendation

Homeowners should:

  • Avoid high-MERV 1-inch filters unless the system is designed for them
  • Have static pressure checked if the furnace cycles off frequently
  • Ensure thermostat wiring matches the equipment design
  • Schedule professional diagnostics instead of guessing at furnace size

Need Furnace Repair in Buffalo Grove, IL?

Four Elements Service provides expert furnace diagnostics, airflow testing, and heating repairs throughout Buffalo Grove and surrounding areas.

📞 Call: 847-350-8141
📧 Email: [email protected]
🌐 Website: fourelementservice.com


What caused the heating failure in the Buffalo Grove home?

The heating failure was caused by high static pressure and incorrect installation, including airflow restrictions, improper thermostat wiring, and a restrictive air filter, which led to the furnace overheating and shutting down.

How does high static pressure affect a furnace’s operation?

High static pressure restricts airflow, causing the furnace to overheat, short cycle, and potentially fail prematurely, as it prevents proper heat exchange and safety functioning.

Why did the high-MERV 1-inch filter contribute to the furnace issues?

The high-MERV 1-inch filter significantly restricted airflow, which caused the furnace to overheat and trip the high-limit switch, leading to system shutdowns.

What correction measures were taken to fix the furnace problems?

The technician corrected thermostat wiring, removed the restrictive filter, recommended appropriate filtration options, and tested the system to ensure safe and continuous operation.

What are the key recommendations for homeowners to prevent similar furnace issues?**

Homeowners should avoid high-MERV filters unless system-designed, check static pressure if the furnace cycles frequently, ensure proper thermostat wiring, and schedule professional diagnostics instead of guessing furnace capacity.

  • Heating Failure Caused by Static Pressure and Installation Issues: High static pressure and improper installation, including airflow restrictions and wiring problems, led to the furnace overheating and shutting down.
  • Impact of High Static Pressure on Furnace Operation: High static pressure restricts airflow, causing overheating, short cycling, and potential premature component failure.
  • Role of Restrictive High-MERV Filter in Furnace Issues: A high-MERV 1-inch filter significantly restricted airflow, leading to overheating and system shutdowns.
  • Corrective Actions Taken to Repair Furnace Problems: Thermostat wiring was corrected, restrictive filters removed, proper filtration recommended, and system tested for safe operation.
  • Key Recommendations for Homeowners to Prevent Furnace Issues: Homeowners should avoid high-MERV filters unless system-designed, check static pressure, ensure proper wiring, and seek professional diagnostics.

author avatar
George Service field manager
George Stahov is an HVAC engineer with over 12 years of experience in heating, cooling, and refrigeration. As the owner of Four Elements Service, he specializes in high-efficiency system design, diagnostics, and installation. Recognized with professional awards from Carrier and Mitsubishi, George provides trusted, expert insights for homeowners and businesses.